NI80 fused Alien Fused Claptons
            £9.99
              Alien FUSED Clapton 
26Ni80*38Ni80 .10 3mm ID
DUAL
A
 perfect blend of ni80 round wire bringing you the best performance
 possible for your vaping experience, this type of coils is well suited 
for that all round flavour and cloud production handcrafted to 
perfection each and every time. 
You will have to agree to our terms on coil misuse at the checkout before purchasing this product.
All
 wicked wires uk coils are sterilised prior to packing and go through a 
triple stage quality check process before being packaged for postage to 
our customers.
How to install
Some coils may ohm lower than your device can fire (
staggertons .08-.10Ω, 
framed staples .12Ω)
 in this instance it is advised to fit one coil at a time, if using a 
regulated device use a low wattage, 15-25 watts depending on the ohm of 
the coil,trim the legs of both coils to the desired length required by 
your device, fit each coil to its dedicated posts ensuring you are using
 the correct posts for your device.
Ensure all 
coil legs are cut to length evenly, correctly and any trailing wires 
have been removed. Check that none of the coils are touching any of the 
externals of the rda they are fitted too or the 510 pins for single coil
 setup devices.
It is advised to now remove the
 grease and oils that have been applied to the coil from your hands 
during fitting, by either using an ultra sonic cleaner or some hot soapy
 water and a clean small soft nylon brush to clean the coils (remove 
from vape device when doing this) give the coils a good rinse in hot 
water and refit to your vape device at a low wattage.
Ensure
 that post screws are not tighten too tight as this can damage the legs 
on more fragile coils such as fused staples and cause the legs to snap 
at the post holes, this can also cause the coil to read incorrect ohms 
when in use (some fluctuation of final ohms readings are a good 
indication of damage caused by incorrect fitting in this manner, usually
 seen at the re-wick stage of coil care and a good indication of coil 
replacement needed) 
Once happy with the fit of
 the coils check there are at the same height as the air flow holes on 
your rda cap, by inserting the coiling tool and gently lifting or lower 
the coil into place, again making sue that both coils are not touching 
any parts of the rda accept where they are secured into the post holes.
Apply
 power to the coils and bring to a gentle amber glow, hot spots may 
appear in the form of bright white/red spots, to remove these, 
discontinue applying power to the coils and strum the coils using your 
ceramic tweezers, or pull the individual coils of the coil apart (hot 
spots are generally caused by the individual coils of the coil touching 
and causing a short)
how to maintain wicked wires uk coils.
If
 you find you have one coil heating quicker then another, check both 
coils are set at the same distance from the posts that they are 
connected to, check the ID (inner diameter) of each coil has not been 
changed due to the fitting process, by using the correct size coiling 
tool and gently tugging on each coil to correct that coils ID.
(ensure
 the coils are secured in place correctly before doing this, wicked 
wires uk is not responsible for any damage caused to coils during the 
fitting process, we advise only experienced vapers use our coils due to 
this)  
How to maintain wicked wires uk coils  
After
 some use the coils may begin to look a little black or dark, this can 
easily be cleaned off by using some of the following steps.
Take
 your rda off of your device and put onto an ohm reader or a regulated 
device with fully charged batteries (DO NOT PERFORM THIS STAGE ON A 
MECHANICAL DEVICE)
Gently 
dry burn your coils by removing your wick, apply low power to your coils
 at around 20-30 watts to produce a low amber glow, as this occurs any 
sugars that have built up on the coils should burn away, once this 
begins release the power on your device and set to one side to allow the
 device and the coils to cool naturally.
(DO NOT RUN UNDER WATER) 
Once
 the device and coils have cooled, remove your rda/rdta from your 
device, take to a sink and wash the coils and rda with a soft nylon 
brush (toothbrush works well) and some warm soapy water, with more 
complex coils be gentle if using this process to clean coils. give the 
coils and rda a good rinse with clean warm/hot water and shake off 
excess water before fitting back to your device.
(wicked
 wires uk recommend you use an ultra sonic cleaner for long term 
solution for this process with 2 or 3 cycles run if possible) 
You
 should now perform the same steps as you did when you fitted the coils 
from new, to ensure all the screws in the posts are still tight after 
being cleaned, that the coils themselves have not degraded to a state 
that they require replacing, check the integrity of the insulators on 
your rda before applying power to it again, check that the 510 pin on 
the rda/rdta is correctly tightened and then re-glow both coils to 
ensure they are glowing evenly (if in doubt follow the first steps in 
these how to tips) 
Once happy with the cleanness and fit of the coils allow to cool, re-wick and vape!
(wicked
 wires uk is not responsible to damaged caused to coils/rda/rdta/mods or
 any individual due to incorrect fitting, or caused due to general 
maintenance or use of wicked wires uk hand made coils, the information 
and tips described above are to be used at the customers own risk and as
 a general how to guide, you should be sure you have sufficient 
knowledge of ohms law, correct battery safety and general use. That you 
have a good understanding of how to use rebuild-able vape devices and 
when purchasing wicked wires uk coils you do so at your own risk)